skip to main |
skip to sidebar
Labels:
Flues,
Masterflue,
Quick installation
Airtherm Engineering's reputation for providing a quick response to clients needs was highlighted by a recent flue installation at student accommodation in Manressa Street (off Kings Road), Chelsea, London.
The client contacted our office to request an engineer to attend site, survey and provide a price the same day. After our initial survey we offered our cost proposal for consideration, after which an order was issued but only on the provision that we could install both flues within 48 hours due to exceptional time constraints.
The product required was in stock and the installation was completed within the 48 hour deadline, much to the delight of our client.
Consultant: Shaylor
Client: MVS Ltd
Sector: Education
Products: MasterFlue System
Equipment: Andrews Water Heater
Application: Atmospheric
Water Heater: Andrews Water Heaters
Model: Ecoflo EC380/1900
Application: Chimney / Flue system
Operating mode: Wet
Pressure: Positive
Working pressure: 200 Pa (product will operate 1000pa max)
Inner wall: 316L1.4404/1.457 thickness Ø250 0,4 mm
Outer wall: AISI 304/ 1.4301 thickness 0,5mm
Insulation: None
Sealant : Tri-lip 'o' type silicone ring
Fuel type: Gas
For more information: www.airtherm.co.uk
Labels:
Flues,
Masterflue,
Natural Lighting,
Solatube,
Twin Wall
Airtherm Engineering Limited worked with Trendgrey Construction Limited to complete the installation of a twin wall stainless steel, four hour fire rated flue installation at Crackley Hall School, Kenilworth. We also installed our Solatube Day Lighting system in several classrooms and corridors.
The new extensions at Crackley Hall School will provide new specialist classrooms, a new hall and music centre. As Crackley Hall is a historic building and is set within a residential context, we worked closely with our client and the local planning authority to develop an appropriate solution for the termination of the products of combustion.
Consultant: Ridge & Partners
Client: Trendgrey Ltd
Sector: Education
Products: MasterFlue System / Solatube Daylight Systems
Equipment: Ideal Harrier / Solatube 160DS
Application: Blown Gas / Flat Roof
Flue solution -
Water Heater: Ideal Cast Iron Boiler
Model: GT Harrier 5
Application: Chimney / Flue system
Operating mode: Dry
Pressure: Negative
Working pressure: 200 Pa (product will operate 1000pa max)
Inner wall: 316L1.4404/1.457 thickness Ø250 0,4 mm
Outer wall: AISI 304/ 1.4301 thickness 0,5mm
Insulation: 25mm thick
Sealant : Tri-lip 'o' type silicone ring
Fuel type: Gas
Lighting solution -
Product Type: Solatube
Model: Solatube 160DS
Light Coverage: 1032sq m (each)
Number of Solatubes: 5off systems
Location / Areas: Classroom & Corridor
Roof Application: Flat
Roof Type: Sarnafil
Day Lighting systems actively capture daylight from the rooftop and project through a highly reflective tubing to where it’s needed. Solatube light tube system uses the most advanced technologies to ensure that the efficiency and performance of their systems is unrivalled.
Extension tubes are available in lengths of 610mm (straight) or 380mm long incorporating a 0-30° adjustable angle along with the new 0-90° angle unit. All reflective tubes – including adjustable tubes – are manufactured from 99.7% reflective Spectralight Infinity material, allowing tube lengths of up to 15 metres for the SolaMaster 330 DS.
OPTIVIEW® DIFFUSERS
The technologically advanced OptiView® diffuser uses a multiple Fresnel lens system with a stunning architectural look to deliver crystal clear daylight.
For more information: www.airtherm.co.uk
Labels:
Chimneys,
Flues,
Masterflue,
Twin Wall
During September 2012, Airtherm Engineering Limited completed a flue installation at All Saints Primary School, Maidenhead, ready for the return of pupils from the summer shut-down.
The Masterflue system installed incorporated a draft stabiliser, as recommended within the manufactures operating and maintenance literature for balancing purposes.
Due to the close proximity of a kitchen ventilation intake (AHU) - approx. 5m distance - the flue system couldn't simply terminate above the flat roof as standard. Instead, our solution was to incorporate an offset towards the taller structure with the twin wall flue system fixed and secured to the existing brick stack.
Consultant: Maidenhead Council
Client: Perfect Pipework Ltd
Sector: Education
Products: MasterFlue System
Equipment: A.O. Smith COF315
Application: Atmospheric
Water Heater: AO Smith
Model: COF315
Application: Chimney / Flue system
Operating mode: Dry
Pressure: Negative
Working pressure: 200 Pa (product will operate 1000pa max)
Inner wall: 316L1.4404/1.457 thickness Ø250 0,4 mm
Outer wall: AISI 304/ 1.4301 thickness 0,5mm
Insulation: 25mm thick Rockwool insulation
Sealant : Tri-lip 'o' type silicone ring
Fuel type: Oil
Other Application METALOTERM MasterFlue:
• Condensing boilers
• Atmospheric gas-fired boilers
• Gas blown boilers
• Industrial ovens, large-scale establishments
• Wood-fired stoves
• Other Advantages METALOTERM MasterFlue
• No terminal bridges, better heat protection
• High-temperature silicone sealing ring
• Fast-build system without the need of sealants
• High quality insulation uninterrupted from base plate to top stub
For more information: www.airtherm.co.uk
Labels:
Flues,
Hamworthy,
Masterflue
During December 2012, Airtherm Engineering worked closely with the contractor at Raich Leisure Centre in Sunderland to complete the installation of a Hamworthy Masterflue system.
The flue system installed comprised of a 3m horizontal run and a 7m vertical, incorporating the necessary drains to allow any unwanted condense to evacuate the system.
Our engineers had been given only ten days to arrange both a site meeting and install the complete flue system to meet our clients program. Not only did we fulfil our obligation but Airtherm were a massive 15% cheaper than the boiler manufacture’s own preferred company (on a ‘like for like basis and using the exact same Masterflue( MF) product range).
Consultant: Sunderland Council
Client: RM Myers & Co Ltd
Sector: Leisure
Product: MasterFlue System
Equipment: Hamworthy 220/660he
Application: High Efficiency
Boilers: Hamworthy
Model: 2 x Modumax 220/660he
Application: Chimney / Flue system
Operating mode: Dry / Wet
Pressure: Positive pressure
Working pressure: 200 Pa (product will operate 1000pa max)
Inner wall: 316L1.4404/1.457 thickness ≤ Ø250 0,4 mm, ≥ Ø300 0,5 mm
Outer wall: AISI 304/ 1.4301 thickness 0,5 / 0,6 mm
Insulation: 25mm thick Rockwool insulation
Sealant:Tri-lip 'o' type silicone ring
Fuel type: Gas
Other Applications of the METALOTERM MasterFlue:
• Condensing boilers
• Atmospheric gas-fired boilers
• Gas blown boilers
• Industrial ovens, large-scale establishments
• Wood-fired stoves
• Other Advantages METALOTERM MasterFlue
• No terminal bridges, better heat protection
• High-temperature silicone sealing ring
• Fast-build system without the need of sealants
• High quality insulation uninterrupted from base plate to top stub
For more information: www.airtherm.co.uk
Labels:
Chimneys,
David Brown,
Flues,
Kitchen Canopies
Airtherm are pleased to announce the appointment of David Brown, who joins our vibrant and enthusiastic team of individuals, in the capacity of Associate Director.
David has 22 years of sales experience in commercial and industrial heating & ventilation. He has worked for some large, well-known corporate companies, as well as a close competitor for 9 years, where he previously held the role as Renewables Manager and specialised in Natural Ventilation, Ventilation Controls and Natural Lighting Systems.
He also has an extensive knowledge of Chimney & Flue and Commercial Kitchen Canopy systems. David also has a wealth of experience in the field of Health & Safety which brings an added value to our business.
David will be a welcome addition to the company.
Airtherm have also appointed Technical Sales Engineers covering the North West, East Midlands, West Midlands, North Wales, London & Scotland.
If you have any enquiries in these locations, please call our office on 0844 809 2509 or email sales@airtherm.co.uk to arrange a meeting.
For more information: www.airtherm.co.uk